Акумулатор усисног вода trap that prevents the компресор from taking slugs refrigerant liquid or compressor oil. This is a very simple device that serves a very important function. When fluid is supplied to the compressor noise, high consumption, and most importantly compressor damage, likely to result.

The system, which, as a rule, require the accumulator are those that:

  1. Wide or rapid changes in load.
  2. There are a lot of steps capacity control or complicated regulation system performance.
  3. Are heat pump systems.
  4. The use of hot gas defrosting of the refrigerating reel or coil heat pump.
  5. Required replacement of the compressor due to the ingress of liquid refrigerant.

акумулатор усисног вода also serves as a temporary storage of liquid refrigerant chamber for some systems and heat pumps. This is necessary if the system requires different operating refrigerant in the cooling mode, than it is done in heating mode.

If the original equipment requires liquid accumulators, they are installed by the manufacturer.

Split-system sometimes include a factory install a battery in the condensing unit. This is especially true on the model it is assumed that the manufacturer of premium product line. Another time, split systems may require additional battery in the field. If necessary, in the settlements system, batteries, as a rule, on-site installation.

Batteries are installed in the suction piping, as the suction pipe of the compressor as possible. In this place any liquid coolant or oil, which returns in large quantities is trapped temporarily in the battery. The tube bottom, leaving a battery in this scheme takes the oil back to the compressor.

Slugs of liquid refrigerant entering the battery trapped until they can evaporate back into pairs. The evaporated refrigerant joins the rest of suction gas flow and exit from the top of the reservoir. Battery shown here there is a heater in which he was wrapped. Heater speeds up re-evaporation of liquid refrigerant. Not all batteries have such heater.

In this model, the suction of the gas coming from the евапоратор coil " dummy " in the right top of the battery. Liquid bullets directed against the right wall of the battery casing and run down. Refrigerant vapor enters the tube top and removed to the compressor suction. Dosing hole in the bottom of the return pipe slowly sends refrigerant oil back to the compressor through the suction line. If a heater is wrapped around the battery, re-evaporation of liquid refrigerant proceeds more quickly. Otherwise, the heat of the air surrounding the battery determines the rate of evaporation.

Suction line batteries great insurance policy against damage to the compressor tubes that can occur in conventional air conditioning. As with any traps battery has the potential to prevent the needed oil from returning to the compressor. The correct selection and installation of the battery, plus maintenance of the systems of cleaning conditions that this does not happen. The battery must be sized to adequately handle normal liquid flow coming from the evaporator. Even when the design and installation are done correctly, a serious failure in the system may still cause fluid overflow battery and bullet compressor...

 
Хвала ->



Класификација расхладних средстава Релеј покретања компресора Испаривач за суво ширење Расхладни систем расхладног средства Спољно изједначени термостатски експанзијски вентил Коса влажна Отворите погонски компресор Шифре боја цилиндра за расхладно средство Хладни компресор Полу херметички вики компресор Вики за клизни компресор Систем хлађења на парни млаз Врсте кондензатора